BIOS CONFIGURATION
70
3.7.5.9 Controller Fan Detection
Included in the product box is a eld replaceable passive heat-
sink to be used only if there is enough airow to adequately cool
the passive heatsink.
The “Controller Fan Detection” function is available in the rm-
ware for preventing the buzzer warning. When using the passive
heatsink, disable the “Controller Fan Detection” function through
this McBIOS RAID manager setting.
The following screen shot shows how to change the McBIOS
RAID manager setting to disable the beeper function. (This
function is not available in the web browser setting.)
I/O Port Addr : 28000000h, F2(Tab): Select Controller, F10: Reboot System
ArrowKey Or AZ:Move Cursor, Enter: Select, ESC: Escape, L:Line Draw, X: Redraw
Areca Technology Corporation RAID Controller
Main Menu
Quick Volume/Raid Setup
Raid Set Function
Volume Set Function
Physical Drives
Raid System Function
Ethernet Conguration
View System Events
Clear Event Buffer
Hardware Monitor
System information
Raid System Function
Raid System Function
Mute The Alert Beeper
Alert Beeper Setting
Change Password
JBOD/RAID Function
Background Task Priority
SATA NCQ Support
HDD Read Ahead Cache
Stagger Power on
HDD SMART Status Polling
Controller Fan Detection
Auto Activate Raid Set
Capacity Truncation
Stagger Power on
Stagger Power On
0.4
0.7
1.0
1.5
.
.
6.0
I/O Port Addr : 28000000h, F2(Tab): Select Controller, F10: Reboot System
ArrowKey Or AZ:Move Cursor, Enter: Select, ESC: Escape, L:Line Draw, X: Redraw
Areca Technology Corporation RAID Controller
Main Menu
Quick Volume/Raid Setup
Raid Set Function
Volume Set Function
Physical Drives
Raid System Function
Ethernet Conguration
View System Events
Clear Event Buffer
Hardware Monitor
System information
Raid System Function
Raid System Function
Mute The Alert Beeper
Alert Beeper Setting
Change Password
JBOD/RAID Function
Background Task Priority
SATA NCQ Support
HDD Read Ahead Cache
Stagger Power on
HDD SMART Status Polling
Controller Fan Detection
Auto Activate Raid Set
Capacity Truncation
Controller Fan Dectection
Controller Fan Detection
Enabled
Disabled
values can be selected from 0.4s to 6s per step which powers up
one drive.