Lens Data Display LDD-FP 125
Zoom Main Unit ZMU-3
The ZMU-3 controls the the zoom axis. It can be connected to the camera
via cable to an LCS port, or via cable through an LCS port of an WCU-3, or
wirelessly by using a WZE-3.
Wireless Zoom Extension WZE-3
The WZE-3 is a radio system that enables direct wireless connection of a
ZMU-3 and a camera.
Hand Unit Priorization
Different priority levels are assigned to the hand unit devices to ensure only
one device has control over a motor at a time.
A device's knob that is assigned to an axis has a higher priority than a
device's slider assigned to the same axis. When steering items of the same
type are assigned to the same axis, the one connected via WRS has highest
priority, second highest priority has a device cable on the upper LCS port,
the lower LCS port has the lowest priority. Of two radio devices with the
same steering items assigned to the same axis, the one that connects to the
camera first gains control.
Cabled devices can gain control of an axis at the time of connection.
Wireless devices must be rebooted if an axis has become idle before they
can gain control.
An exception to the rule are devices on the zoom axis. Here the cabled
devices have the highest priority, with LCS port 1 having priority over LCS
port 2.
13.5 Lens Data Display LDD-FP
The Lens Data Display for Focus Pullers LDD-FP can be used to display
lens information. Connect it to the LDD port of the ALEXA Plus.