Installation
42 EN 03|2022
5.3 Electrical connection (Qualified specialist)
Only apply power when the housing is closed with the
transparent lid.
Electrical connections must always be carried out by
authorised specialists.
Observe VDE and utility company regulations.
Install pumps for swimming pools and their protection
according to DIN VDE 0100-702.
Observe DIN EN 60730 part 1.
Î Install a disconnecting device with at least a 3 mm contact
gap per pole to interrupt the power supply.
Î Protect power supply with a ground fault circuit interrupter,
nominal residual current I
FN
≤ 30 mA
Î Only use suitable pipe types according to regional
regulations.
Î Adjust minimum diameter of the electrical pipes to
accommodate the motor output and pipe length.
Î If hazardous situations can occur, provide an emergency off
switch according to DIN EN 809. The builder/operator must
make a decision according to this standard.
Pos: 47.11 /Tec hnische Dok umentation Sp eck Pumpen/B etriebsanleitung/ Installation/El ektrischer A nschluss/BADU Tr onic/Bauseitiger Anschluss Tro nic @ 8\mod_ 14751408733 52_370.docx @ 9 9001 @ @ 1
Î Connection by customer:
Fuse protection 1 phase 230 V/3 phase 400 V safety fuse
10 A time delay
Rated short circuit breaking capacity I
CN
≤  A
Î Black plug terminals and pins carry voltages up to 230 V.
Green plug terminals and pins may only be connected
potential-free.
Î Before voltage is connected to the control, all pin strips must
be occupied by the appropriate plug terminals.
Î Mains power supply (L,N) 230 V, 50/60 Hz (continuous
voltage)