EasyManua.ls Logo

BADU OmniTronic - Digital Inputs (DCX, Acx)

BADU OmniTronic
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description
30 EN 03|2022
Enable and start must also be connected to contact 20
(com/0V)
De-energize the frequency converter
Restart the frequency converter
Î See point 5.3.7 on page 46.
Pos: 36.46 /Tec hnische Dok umentation Sp eck Pumpen/B etriebsanleitung/ Beschreibu ng/BADU Omnitr onic_ BADU Om ni Stellantrie b/Digital-Ei ngä nge @ 1 6\mod_15 80138001514 _370.docx @ 3 20984 @ 3 @ 1
3.6.6 Digital inputs (DCx, ACx)
The digital inputs can be used as follows:
Input no. 1: Start backwash process (signal must be applied for 3
seconds)
Input no. 2: Switch on filter pump (in lowered position filter). The
previously set speed n1 to n3 is running. The released speed
stage can be changed in the interval mode.
Input no. 3: This is used for special functions.
DC1, DC2 and DC3 must be used for potential-free contacts:
Î See the terminal diagram!
DC1: for potential-free contacts, for example, pressure switch at
the valve/filter
Function: When the pressure switch (t>3s) is triggered, a
backwash/rinse cycle is started (available optionally; article no.
260.6402.087)
DC2: for potential-free contacts, for example manual, external
switches. If 24-hour filtering is wanted, a bridge must be set from
DC2 to GND.
Function: The pump switches to the “Filter” position as soon as
the switch is closed.
DC3: for potential-free contact, e.g. dry run protection
Function: Trigger at start pump (time A up to 60 s) and trigger
time of pump within the operating time (time B up to 60 s) and
reset. The display -” stands for manual reset, the display “%”
means that the pump starts running again after 15 minutes.
AC1, AC2, AC3 and N must be used for 230 V-bearing signals:
Î See the terminal diagram!
Pay special attention to phase L and neutral N of the
BADU OmniTronic and the general voltage-bearing cables!