20 EN 03|2022
There is a choice between simple and
extended display. In the simple display,
some information is not shown on the main
screen.
Factory setting: simple display.
All values can be reset to factory settings
with Reset.
General functions
Frost protection
The frost protection can be switched on or
off under Status. In addition, three different
pump speeds can be defined at different limit
temperatures for speed-controlled pumps.
The maximum temperature applies for
pumps without speed control.
Sensor level control
Different functions can be set for the three
level sensors. The sensors therefore trigger
different actions.
---: no action
Niv: Level control
DC1: RS-Start (corresponds to the
same designation as for the digital input
for RS)
DC2: Filter pump working (corresponds
to the same designation as for the
digital input for FIL)
RxA: Switching output R_x switches on
permanently after a 7 s delay and off
again in the same way when the input is
no longer available (x here is the relay
R_1 or R_2 on the board which can
output optionally)
RxB: Switching output R_x switches
several pulses after a 7 s delay and
more after another 5 minutes for as long
as the input is available. At the same
time, the horn signal on the board (x
here is the relay R_1 or R_2 on the
board which can be output optionally)
operates