EasyManua.ls Logo

Barco SilverWriter 800 - Copying Parameters between Two Maccons; Copying Parameter between Two Maccon

Barco SilverWriter 800
276 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Field Service Manual December 2003
Page 133 of 276
Copying parameters between two Maccon’s
For copying parameters between two Maccons one can use the LTL command
copypar.
COPYPAR
is used to copy LTL-parameters between 2 maccon boards. Therefore, a
second maccon must be installed on an extender board in the copyslot of the macbpl.
Procedure:
· Switch off power.
· Disconnect the short serial cable between maccon and ssipro.
· Put an extender board in the place of the copy slot of the macbpl.(left of ssipro)
· Mount second maccon on the extender board.
· Install short serial cable between the two maccons on line 2.
· After powering-up and booting the maccon to LTL-mode, the LTL word COPYPAR
can be used (HRDWINIT is not necessary)
LTL > COPYPAR
...
(1) from master to slave
(2) from slave to master
Your choice : x
Are you sure [Y/N] ? x
Master : maccon in maccon slot
Slave : maccon in copy slot (on extender)

Table of Contents