EasyManua.ls Logo

Barco SilverWriter 800 - Adjustment Procedure Optics 600

Barco SilverWriter 800
276 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Field Service Manual December 2003
Page 184 of 276
Adjustment procedure Optics 600
Setting the default parameters
The following parameters must be filled in before "DEFAULTS" can be
executed:
the machine type in par 1:
7600
the base resolution in par 95:
4000
the resolution in par 4:
4000
the nominal drum speed in par 18:
26000 ((par18)untill 20320ppi)
G table depending
number of beams par 5:
24
X-Y expand factor in par 10-11:
0
Execute "DEFAULTS":
Remark ! ! ! : Machines at customers side are already setup. So be
carefull using defaults. Defaults will set your tables to
standard settings !!!
LTL > defaults
is it a drv4x3 [Y/N] ? y
upgrade M-table dcdbdv-->drv4x3 [Y/N] ?
Quality (0) or Speed (1) = 0
Defaults for RF-FREQUENCIES [Y/N] ?
Defaults for beam-pin configuration [Y/N] ?
Defaults for thicknesses and ysizes [Y/N] ?
Defaults for DELAYS [Y/N] ?
Defaults for TUCOR [Y/N] ?
Reset knife_corrections [Y/N] ?
Upgrade knife_corrections optics300-->600 [Y/N] ?
Defaults for legal ppi [Y/N] ?
Defaults for lock range [Y/N] ?
Defaults for SKYMAX [Y/N] ?
Do not forget PROPAR if you want to store these values
If you want to save these values do not forget PROPAR
LTL > PROPAR
Execute "LOCKRANGE_ALL".