Field Service Manual December 2003
Page 184 of 276
Adjustment procedure Optics 600
Setting the default parameters
• The following parameters must be filled in before "DEFAULTS" can be
executed:
• the machine type in par 1:
7600
the base resolution in par 95:
4000
the resolution in par 4:
4000
the nominal drum speed in par 18:
26000 ((par18)untill 20320ppi)
ᄕ G table depending
number of beams par 5:
24
X-Y expand factor in par 10-11:
0
• Execute "DEFAULTS":
❖
❖❖
❖Remark ! ! ! : Machines at customers side are already setup. So be
carefull using ‘defaults’. Defaults will set your tables to
standard settings !!!
LTL > defaults
is it a drv4x3 [Y/N] ? y
upgrade M-table dcdbdv-->drv4x3 [Y/N] ?
Quality (0) or Speed (1) = 0
Defaults for RF-FREQUENCIES [Y/N] ?
Defaults for beam-pin configuration [Y/N] ?
Defaults for thicknesses and ysizes [Y/N] ?
Defaults for DELAYS [Y/N] ?
Defaults for TUCOR [Y/N] ?
Reset knife_corrections [Y/N] ?
Upgrade knife_corrections optics300-->600 [Y/N] ?
Defaults for legal ppi [Y/N] ?
Defaults for lock range [Y/N] ?
Defaults for SKYMAX [Y/N] ?
Do not forget PROPAR if you want to store these values
If you want to save these values do not forget PROPAR
LTL > PROPAR
• Execute "LOCKRANGE_ALL".