Field Service Manual    December 2003 
 
 
    Page 80 of 276
MF Electrical Solid State panel 
 
Used for: 
Film detection Bridge.     Input detection 3     Is one when film is detected 
End detection Film plate.          Input detection 1
(Flatcable)  Is one when film plate back is detected 
 
Start/stop Motor Film plate.    Solid state number 1(at det SS)  SIOREL/RIOREL 1 
      0 motor stopped 
REMARK: 
Following command line should be used to move the motor in LTL: 
1 siorel 5e5 wait 1  riorel (No limit protection within LTL!!!!) 
Left/right movement Motor Film  Solid state number 2  SIOREL/RIOREL 2 
      0 motor moves backwards 
Blow pipe command    Solid state number 3  SIOREL/RIOREL 4 
       0 Blower is off  
Extended position Roller    Solid state number 4  SIOREL/RIOREL 8
 
RMF1 : Motor direction 
RMF2 : Motor activating 
 
 
 
 
 
 
 
 
G101300 