EasyManua.ls Logo

Barco SilverWriter 800 - Parameter List; Parameters:: Explanation

Barco SilverWriter 800
276 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Field Service Manual December 2003
Page 137 of 276
Parameter list
Parameters : : explanation
1 Machine type : 7600
- indicates the type of machine
2 Beam_dpi combinations : -536870401
- indicates the choosen options of the optics.
- will be automatically calculated by entering
the options. (B-command: see later)
3 Chart home position (1/6400 mil) : 975000000
- defines the origin of the film along the drum for filmt0.
The plot position in X-direction is controlled by parameter 3 (carriage
home position) which unit is 1/6400 mil or 0.00397 µm. Increasing
/ decreasing the value of this parameter will decrease / increase
the gap between the left side of the job and the left side of the film.
Example:
The following is an example of how to move the left side of the job 5
mm closer to the left side of the film, supposing the value of parameter
3 is now 120000000.
Calculation of change to parameter 3: 5 mm = 5000 µm
5000 / 0.00397 = 1259446
new value of parameter 3 = 120000000 + 1259446 = 121259446
4 Resolution : 4000
- defines the resolutions of the plotter
Beams in use : 24
-Beams in use : indicates the maximum number of
beams that can be used. Depending on scaler.
5 Number of beams : 24
- defines the number of beams for expose
6 Index to film gap (1/32mil) : 300000
- defines the zero point around the drum
The plot position in Y-direction is controlled by parameter 6
(index to film gap) which unit is in 1/32mil. Increasing /
decreasing the value of this parameter will increase / decrease
the gap between the top side of the job and the top side of the
film.

Table of Contents