Field Service Manual    December 2003 
 
 
    Page 15 of 276
SilverWriter MF Site Preparation Checklist  
 
 
Customer code:         
  Plotter type:  
 
Customer contact 1:…………………….. Function: ……………………………... 
Customer contact 2:…………………….. Function: ……………………………… 
Customer contact 3: …………………….. Function: ………………………………... 
Customer contact 4: …………………….. Function: ……………………………… 
 
Installation address: 
  …………………………………………………………………………………….. 
 ……………………………………………………………………………………..
 ………………………………………………………………………………….. 
 ……………………………………………………………………………………….. 
 
 
Plotter size: width=1725mm, depth=2358mm, min depth=1500mm, height=1825mm, service 
height=2480mm, weight=1500 kg 
Crate size:
 width=2010mm, depth=2766mm, height=2079mm, 500 kg (2000 kg with plotter) 
    
 
 
  Has the customer received the pre-installation manual?   Yes   No 
 
 Does the customer have a storing place for the crate?   Yes   No  If 
no, plastic must be available to cover the crate 
 
  Forklift truck to unload plotter from truck (2000kg load, long blades) must be 
available 
 
  Manual forklift (1500kg) must be available during installation 
 
  The entrance for the plotter and corresponding passageways or corridors 
must be free from obstacles 
 
  Is the floor (including passageways) stable enough?   Yes   No 
(install thick metal plates) 
 
  Does the floor of the plotter room need to be reinforced?   Yes   No 
 
  Will a film processor be online connected to the plotter?   Yes   No 
 
 
  The plotter room must be big enough (+1.5m space at drawer side, +1m 
space at front and right side, 2.5m height) 
 
  Vibrations must comply with specs, in case of doubt contact specialized 
company 
 
  Vacuum pump box must be installed in a dry and clean area (max temp 30°C) 
outside the plotter room. 75dB , 2.7kW at 250mbar , 50 
°C
 
 
  Vacuum tube length to plotter → maximum 15m, outer ∅ = 72mm 
minimum (supplied by Barco) 
 
  Vacuum pump box command cable connector ∅ = 35mm (supplied by 
Barco)