Field Service Manual December 2003
Page 180 of 276
Electronic boards in the machine rack
The machine rack is placed at the bottom (above the ventilators) and
contains the following new boards (see drawing 39923):
• PE 4136/01
5V - 20A; 24V - 2.8A; +12V - 2A; -12V - 2A; -5V - 0.5A.
The power of the 24 volt is increased (24 volt used in multibeam box)
• MONOVOLT SUPPLY PK400
40 VOLT SUPPLY (8-10 Ampere)
• Maccon
• ADAPTED FOR RSF-SCALE
• ADAPTED FOR BEAM TUNING
• Generation of the pixel clock
• I2C-interface
• Correction of shaft encoder eccentricity
• Ssipro
As a consequence of the "interlaced exposure principle", the expose
data coming from the RIP has to be shuffled and delayed before it can
be sent to the optics.
• CARLAS
Drives the shutter.
• MULTIBEAM BOX:
There are 2 DRV4X3 boards. Each board generates 3 channels of 4
beams.