Field Service Manual December 2003
Page 264 of 276
Communication
Error : JOB TIME OUT
No communication any more between machine and Rip.
► Hotidle : If not installed with Phifac AMCC chip Earlier than S(39)35
If installed with Phifac AMCC chip ‘S(39)35 or later’ and working
with Smartplot Console
►G table of Maccon parameterlist
► Latest patch on Maccon
► Check parameters and resource files
► Check for other error messages in log file.
► Disable drumcor and secor. Check secor(LTL>dissec).Run secor again.
► Phifac, ca:phifac-ssipro, Ssipro, Maccon
Error : In 'log'file: get_msg(errorxx):Data error(Cyclic Redundancy Check)
Phifac sends data to Ssiproiii together with a checksum(CRC). Ssipro receives
the data, makes also a checksum and compares it with the one from phifac.
When the two CRC's are not the same you get this message.
► Phifac - Ca:phifac-ssiproiii – Ssiproiii
► Incorrect job.
Error : No heart beat enabled
Phifac has no connection with Ssipro
► Phifac--CA:phifac-ssipro—Ssipro
Error : no force_ssipro3_comp found
Probably 4000 added to async resolution but no ',1' in the PR_recorder.res file.
► 4000 should not be enabled anymore as ‘async resolution’ in the ‘powerrip.res’
and ‘PR_recorder.res’