Field Service Manual    December 2003 
 
 
    Page 40 of 276
 
•  Press the M key again 
LED under sw2 flashes on and off. 
With ↑ and ↓ key you can adjust the level to the same value when half of the 
film is off the drum. So it means that when a film is loaded and you will 
remove half the film off the drum the machine should detect it. OR
 high 
vacuum detection value is set between the vacuum value without a film and 
the vacuum value with film.  
Ex.: vacuum with film = 220mbar 
       vacuum without film = 190mbar 
       high vacuum detection is set to 205mbar 
This is the vacuum level were sw2 will switch on. 
 
•  Press the M key again 
LED under +/– flashes on and off 
With ↑ and ↓ key you can adjust the value to 10. 
This is the hysteresis. 
 
•  Press the M key again 
With ↑ and ↓ key you can adjust the last setting to F-2. 
 
•  Press the M key during 5 seconds. The settings are now stored. 
 
To Zero adjust the sensor 
 
Press the ↑ and ↓ key together and the sensor will be automatically zeroed. 
 
Sw1-Sw2: ON = no vacuum detected 
+/-: “- = vacuum” “+ = pressure” 
 
Connections 
 
Brown: +V 10.8… 30VDC 
Blue:    common 
Black:  switch1(pnp 30V 100ma max) 
White: switch2 (pnp 30V 100ma max) 
Gray:   analog (0-5V) 
Error messages: 
 
E-1 Overload current is flowing. LED of overloaded SW1 and/or SW2 blinks. 
E-2 Pressure is applied during zero adjustment. 
E-3 Setting conditions are not satisfactory. 
E-4 This error should not appear. 
--- pressure indication is exceeded.