Drum Micro Master Parameter Table  MM750 
 
 Warning: 
All settings should only be entered by qualified personnel, paying particular attention 
to the safety precautions and warnings. 
 
MM750 : makes the drum spinning during exposure. Drumdirection: when standing 
on the right of the SW(drummotor position) the drum spins clockwise during 
exposure. 
 
To enter the parameters into the Micro Master you have to use the three 
buttons and the 4 digit LED display: 
P 
Use this button to toggle between parameter number and parameter 
value. 
 
Use the white button up to set parameter numbers and values to 
higher values. 
 
Use the white button down to set parameter numbers and values to 
lower values. 
P000 ==> P944 : Parameter numbers 
0000 ==> 9999 : Parameter values 
F000 ==> F154 : Fault codes
 
 
parameter: value  remark  explanation 
 ----------------------------------------------------------------------------------------------------- 
         P001 :  0    displays the actual frequency into P000 
         P002 :  20    acceleration in seconds 
         P003 :  15    deceleration in seconds 
         P004 :  0    smoothing in seconds 
         P005 :  43  =  frequency setpoint 
         P007 :  0    enables front panel buttons 
         P009 :  3  +  to get access to the next set of parameters 
         P013 :  60    maximum motor frequency 
         P017 :  1    smoothing type 
         P018 :  1    automatic restart after fault 
         P051 :  ?    turns to the right 
         P052 :  5      selection control function 
         P061 :  4      brake active 
         P062 :  1      converter active (drum spinning) 
         P064 :  5    additional brake time in sec. (assure full stop) 
         P075 :  200    value of the brake resistor (Ohms) 
         P081 :  50     *  motor nominal frequency (Hz) 
         P082 :  1410      *  motor nominal speed (rpm) 
         P083 :  3.6   *  motor nominal current (I) 
         P084 :  220        *  motor nominal voltage (V) 
         P085 :  0.75      *  motor nominal output (kW) 
         P086 :  150     motor current limit (%)   
         P087 :   ?    PTC enabled 
         P088 :   1      !  enables autocalibration (has to be done once) 
         P089 :   x.x     !  stator resistance (measured during calibration) 
         P122 :   0     disables forward/reverse button 
 