Field Service Manual December 2003
Page 16 of 276
Power cable 230VAC 3phase 25A 6 mm² (protected with 32A very
slow fuse) to the vacuum pump
or Power cable 380VAC 3phase 12A 4 mm² (protected with 25A very
slow fuse) to the vacuum pump
Install transfo if the required Voltages are not available(ex.:from 207V -> 230V)
Customer should provide an UPS for the plotter,will one be available? Yes No
Two 230VAC outlets (1 x UPS 1kW and 1 x 6A) must be available at back left of
plotter
Two 230VAC outlets (1xUPS 500W)must be available for the plotter PowerRip PC
Ground (earth) of power outlets must be interconnected!
At least two 230VAC outlets (UPS 100W) must be available for maintenance
(oscilloscope, lamp,…)
Status lamp (red) mounted against wall of yellow room (230 VAC, light bulb 100
W max) (optional)
Plotter room must be equipped with correct fittings for green safety lamps
(lamp tubes supplied by
Barco)
Tube cyan T20-60cm (x4)
Tube cyan T20-120cm (x2)
Tube cyan T20-150cm (x2)
Plotter room must be equipped with sufficient number of white light fittings
Adequate air conditioning must be available and in working order (temperature,
relative humidity, airflow)
Customer has to provide a transceiver box to connect the plotter to his network
(UTP twisted pair
...)
Working telephone connection must be available in the plotter room for service
purposes
Tables for the plotter PowerRip PC and film box storage must be available
Compressed air connection must be available. 6-10 bar , 2500 l/h
Compressed air filter (water/oil, dust) must be installed on the wall in the plotter
room (0.01mg/m³, 3µm max)
The film processor must be flat on the front towards the conveyor side
Height and distance to first take up roller
Correct chemicals must be available at start of installation
Film processor (installed through the wall) must be ready to work at
start of installation
Films of the right type and size must be available at start of installation
A workstation complying to the Ucam specs with the Ucam/Smartplot software
installed must be available
Does the customer have a densitometer D>5 (is must for AGFA RL7&STD,
KODAK)?
Yes No
Does the customer have a measuring table / tool? Yes No
Light table of correct film size must be available
Does the customer want installation material before the installation? Yes No