Field Service Manual December 2003
Page 153 of 276
Reading parameters from PROM
Expose ? L
-----------------------------------------------------------------
CAUTION Only authorized persons may use this
diagnostics mode, following instructions
from qualified Barco Graphics personnel.
Personal injuries or property damage can
occur if these instructions are not followed.
-----------------------------------------------------------------
To open flmdoor press d and answer ? else after timeout goes on
MPR file par 6 must be in 32milclk units
New ltl word esimul, simulates exposure without moving parts
Max allowed excentricity error is 15 * miltim
LTL > hrdwinit
Initing maccon ... done.
Initing drv4x3 in slot 0 1 ... done.
Initing feeder ... done.
LTL> getysiz
LTL > 1 disysiz
1 CARPOS : 0 (1/6400 mil) --> CORRECTION : 0 (1/32 mil)
2 CARPOS : 400000000 (1/6400 mil) --> CORRECTION : 0 (1/32 mil)
LTL> getyoffs
LTL > 1 disyoffs
[ Q to quit ]
1 CARPOS : 0 (1/6400 mil) --> CORRECTION : 0 (1/32 mil)
2 CARPOS : 400000000 (1/6400 mil) --> CORRECTION : 0 (1/32 mil)
LTL > shwpar
P : PID parameters carriage
F : filmfeed parameters
B : machine configuration
I : diagnostic level
O : supported resolution
N : beam pin configuration
A : multibeam amplitude - tune corrections
M : freq. and delay for base resolution
G : Drumspeed and Resolution table
C : freq. and delays in testjobmode
T : thicknesses per filmtype
E : Listing of expose parameters
Q : quit
Parameter ver 9.0 Your choice : p
31 PID Gain parameter : 12
32 PID P - parameter : 750
33 PID I - parameter : 60
34 PID D - parameter : 3500
35 High speed max acceleration : 20
36 High speed max speed : 16000
37 Acceleration feedforward : 128
38 Velocity feedforward : 18
Parameter ver 9.0 Your choice : p