Field Service Manual December 2003
Page 156 of 276
43 Unload to inline distance : 4000
44 Drum stepper period : 1200
45 Drum stepper acceleration : 4000
46 Load alignment distance : 0
47 Film from drum release time (ms) : 5000
48 Wait before take over (ms) : 1000
49 Wait after take over (ms) : 3000
50 Load drum stepper period : 1200
51 Load drum stepper acceleration : 600
52 Wait after suction caps off (ms) : 5000
53 Wait after blower on (ms) : 2500
54 Timeout inline to online (ms) : 20000
55 Timeout online to processor (ms) : 30000
56 Push blow plate before loading(ms): 4000
57 Drum vac release offst from ldpt 1: 300
58 Winding dis after vac. release : 0
59 Wait after roll down (ms) : 2500
60 Par45 from MM220 vac. pump [0/2] : 2
61 Frnt rol pos after flm rel (0=off): 401
<CR> to continue
62 Back rol pos after flm rel (0=off): 8184
63 Back rol pos after flm rel ( 27''): 7897
64 Back rol pos after flm rel (26''): 7610
65 Back rol pos after flm rel (25''): 7532
66 Back rol pos after flm rel (24''): 7053
67 Wait after loader back multiformat: 0
68 Drum vac release offst from ldpt 2: -980
69 Drum vac release offst from ldpt 3: -980
70 Film in use in LTL mode: 4
Parameter ver 9.0 Your choice : b
24 beam
Dpi = 2000 Bms = 24 Dpi = 4000 Bms = 24
Dpi = 4064 Bms = 24 Dpi = 8000 Bms = 24
Dpi = 8128 Bms = 24 Dpi = 16000 Bms = 24
Dpi = 20000 Bms = 24 Dpi = 20320 Bms = 24
- Multiformat feeder : Y
- Unload in drawer : Y
- MicroMaster RS485 : N
- Load with spindle : Y
- Eph2 : 2048
- SE-mrks : 2048
- Imperial ruling : Y
- RSF linear scale : Y (info)
- BMSHFL : N
- PK240 (40V) : Y
- Auto expose mode : N
- Enable drumcor : N
- Enable secor : Y
- Disable skewness : N
- Disable shver err. : N
- Shinit each expose : N