Field Service Manual December 2003
Page 161 of 276
LTL Rom version M6V11S11.LTL
Reading parameters from PROM
Expose ? L
-----------------------------------------------------------------
CAUTION Only authorized persons may use this
diagnostics mode, following instructions
from qualified Barco Graphics personnel.
Personal injuries or property damage can
occur if these instructions are not followed.
-----------------------------------------------------------------
To open flmdoor press d and answer ? else after timeout goes on
MPR file par 6 must be in 32milclk units
New ltl word esimul, simulates exposure without moving parts
LTL >hrdwinit
Initing maccon ... done.
Initing drv4x3 in slot 0 1 ... done.
Initing feeder ... done.
LTL > cfg
*** Machine Configuration ***
- LTL Rom version M6V11S11.LTL
- Machine type : 7600
- Optics : 12 beam base_resol = 4000
- Shaft encoder : RSF
- Electronics : MACCON SSIPRO
- Driver : drv4x3 in slot 0 1
LTL > getysiz
LTL > 1 disysiz
[ Q to quit ]
1 CARPOS : 100000000 (1/6400 mil) --> CORRECTION : 0 (1/32 mil)
2 CARPOS : 147000000 (1/6400 mil) --> CORRECTION : 0 (1/32 mil)
3 CARPOS : 150000000 (1/6400 mil) --> CORRECTION : -1 (1/32 mil)
4 CARPOS : 153000000 (1/6400 mil) --> CORRECTION : -2 (1/32 mil)
5 CARPOS : 156000000 (1/6400 mil) --> CORRECTION : -3 (1/32 mil)
6 CARPOS : 159000000 (1/6400 mil) --> CORRECTION : -4 (1/32 mil)
7 CARPOS : 162000000 (1/6400 mil) --> CORRECTION : -5 (1/32 mil)
8 CARPOS : 165000000 (1/6400 mil) --> CORRECTION : -6 (1/32 mil)
9 CARPOS : 168000000 (1/6400 mil) --> CORRECTION : -7 (1/32 mil)