Field Service Manual December 2003
Page 165 of 276
- PK240 (40V) : Y
- Auto expose mode : N
- Enable drumcor : Y
- Enable secor : Y
- Disable skewness : N
- Disable shver err. : N
- Shinit each expose : N
- Enable quadding : Y
- Tune each exposing : N
- Tune while accel. : Y
- Enable optic cal. : N
(O)ptics,(M)achine,(E)nable,(Q)uit : Q
Parameter ver 9.0 _ Your choice : t
Reference thicknesses 1/10mil
Thickness[0] = 70 : <cr>
Thickness[1] = 40 : <cr>
Thickness per filmtype in 1/10 mil
Ftype 0 --> 70 Ftype 1 --> 70
Ftype 2 --> 70 Ftype 3 --> 70
Ftype 4 --> 70 Ftype 5 --> 70
Ftype 6 --> 40 Ftype 7 --> 40
Ftype 8 --> 40 Ftype 9 --> 40
Ftype 10 --> 40 Ftype 11 --> 40
[ Q to quit ]
V9.0 Ftype : quit
Parameter ver 9.0 _ Your choice : m
Frequency and delay table for 70 or 40 1/10mil thickness ? 70
FRQ COR DEL FRQ COR DEL
B 0 3000 0 2063 B 1 2694 0 2073
B 2 3111 0 1850 B 3 2795 0 1860
B 4 3207 0 1637 B 5 2902 0 1645
B 6 3305 0 1426 B 7 2997 0 1436
B 8 3403 0 1214 B 9 3093 0 1224
B10 3485 0 1006 B11 3177 0 1016
Add frequency corrections due to knife calibrator [Y/N] ? <cr>
Reset frequency corrections due to knife calibrator to zero [Y/N] ? <cr>
[ Q to quit ]
V9.0 beam : quit
Parameter ver 9.0 _ Your choice : i
[ Q to quit ]
21 Diagnostics level : ______ ______: 513
Diagnostic Info :
- general : Y
- chartcon : N