Field Service Manual December 2003
Page 254 of 276
Can always try a 0 srchwo again.
PID parameters still correct ?
Clean the measuring scale - Clean the head with air pressure.
Is it happening during tunig or skymax performance.
Check all carriage cables. Carriage touching something during
tuning or skymax.
Check 10 zero ohm straps on linear motor.
Try replacing linear scale or Maccon.
Error : No ramping
Carriage wants to start exposing(ramping) but for some reason he does not.
Goes together with no reference counter started(ref counter not stopped).
Maccon - LTLversion
RSF encoder
Error : No ramping : brake mode = 0
Carriage wants to start exposing(ramping) but for some reason he does not.
Just before he starts exposing he wants to open the shutter but it doesnt
work.
Check shutter on different carriage positions.
Probably cable from Electronic rack to Carlass.

Table of Contents