Field Service Manual              December 2003 
    Page 254 of 276 
  ► Can always try a ‘0 srchwo’ again. 
  ► PID parameters still correct ? 
  ► Clean the measuring scale - Clean the head with air pressure. 
  ► Is it happening during ‘tunig’ or ‘skymax’ performance.
 
‼ Check all carriage cables. Carriage touching something during 
‘tuning’ or ‘skymax’. 
 
► Check 10 zero ohm straps on linear motor. 
 ► Try replacing linear scale or Maccon. 
 
 
 
Error :  No ramping 
 
  Carriage wants to start exposing(ramping) but for some reason he does not. 
  ► Goes together with no reference counter started(ref counter not stopped). 
 ‼ Maccon - LTLversion 
  ‼ RSF encoder 
 
 
Error :   No ramping : brake mode = 0 
 
  Carriage wants to start exposing(ramping) but for some reason he does not. 
  ►Just before he starts exposing he wants to open the shutter but it doesn’t 
work.   
   
‼ Check shutter on different carriage positions. 
‼ Probably cable from Electronic rack to Carlass.