Parameters
• Filmfeed parameter 70 = For testing the filmfeeder (in LTL) with the correct
filmsize. And loading a filmsize with the correct parameters.
70 Film in use in LTL mode:
Filmsize around drum
0&1 = 28 inch
2&3 = 27 inch
4&5 = 26 inch
6&7 = 25 inch
8&9 = 24 inch
For a 26inch filmsize around the drum ‘parameter 70’ is 4 or 5.
For a 28inch filmsize around the drum ‘parameter 70’ is 0 or 1.
When ‘4’ is used than the next parameters will be used : Par 79
Par 73
Par 69
Par 64
When ‘0’ is used than the next parameters will be used : Par 3
Par 71
Par 57
Par 62
• Par 3 & Par76 - 84 = Chart home pos >> Defines the origin of the film along the drum for a
certain size around the drum. Around drum
3 Chart home pos (1/6400 mil) : (28inch)
76 Chart home pos filmt1 (1/6400 mil): (28inch)
77 Chart home pos filmt2 (1/6400 mil): (27inch)
78 Chart home pos filmt2 (1/6400 mil): (27inch)
79 Chart home pos filmt4 (1/6400 mil): (26inch)
80 Chart home pos filmt5 (1/6400 mil): (26inch)
81 Chart home pos filmt6 (1/6400 mil): (25inch)
82 Chart home pos filmt7 (1/6400 mil): (25inch)
83 Chart home pos filmt8 (1/6400 mil): (24inch)
84 Chart home pos filmt9 (1/6400 mil): (24inch)
• Par 71-72-73-85-86 = Blower(vacuum pump) off time after film load.
71 Vac off time after load 28''(ms):
72 Vac off time after load 27''(ms):
73 Vac off time after load 26''(ms):
85 Vac off time after load 25''(ms):
86 Vac off time after load 24''(ms):