87R5913197 /02 SP2K-S
7.9 ICMP-X reset
ICMP-X reset possibilities
• The Reboot ICMP-X button in the Control – Power menu of the GUI of the Web Communicator.
• The ICMP-X hardware reset button located on the front panel of the ICMP-X
CAUTION: Using the reset button is not recommended. Only use this as a last resort, when all other
reset possibilities are exhausted. If you decide to use this button, make sure the light source is
turned off to avoid damage to the DMDs of the light source.
How to reset the ICMP-X?
1. Click on the Reboot ICMP-X button in the GUI of the Web Communicator
As a result the projector is safely prepared for the ICMP reboot. All ongoing events on the ICMP (e.g.
ingest) are requested to end. After a few seconds the ICMP is requested to restart. The READY LED on
the front panel of the ICMP starts to blink orange.
The lasers are switched off and the projector remains in ON mode.
Once the READY LED lit continuous green the ICMP-X is up and running.
2. Did the reset of the ICMP-X fail?
► If yes, perform a hardware reset as follows:
1. Switch off the light source of the projector.
2. press the ICMP-X hardware reset button a few seconds (reference 3 Image 7–11) .
Warning: Resetting the ICMP-X with the hardware reset button may cause damage to the
content on the HDDs. A re-configuration of the whole system may be required!
As a result the projector is safely prepared for the ICMP reboot. All ongoing events on the ICMP (e.g.
ingest) are stopped immediately and the ICMP restarts.
Image 7–11
WARNING: Resetting the ICMP-X with the hardware reset button may cause damage to the
content on the HDDs. A re-configuration of the whole system may be required!
ICMP-X