77R5913197 /02 SP2K-S
7.3 What are the possible HDD swaps
General
There are several possible scenarios for replacing (exchange) hard drives on the ICMP-X. The situation is
different depending on the device type (ICMP or ICMP-X) and whether to replace one or more disks.
Continuity of data present on the disks is also impacted depending on the type of exchange. Degraded
operation or RAID initialization may be required.
List of available actions
The following table exposes all possible swaps available concerning HDDs on ICMP-X:
Replacing drives should always be done while the power is off.
Type of HDD swap
On ICMP On ICMP-X
1 HDD replaced.
Content is preserved.
ICMP automatically starts rebuild.
Process takes about 3-4 hours
for 1TB HDD and could takes
about 13-14 hours for 4TB HDD.
Content is preserved.
ICMP-X automatically starts
rebuild.
Process takes about 3-4 hours
for 1TB HDD and could takes
about 13-14 hours for 4TB HDD.
3 HDDs replaced separately
(previous kit of one disk used
three times).
All content will be lost.
RAID initialization need to be
perform with Communicator.
immediately usable after RAID
initialization + restart (content
can be ingested).
All content will be lost.
RAID initialization need to be
perform with Web Communicator.
immediately usable after RAID
initialization + restart (content
can be ingested).
Barco HDD replacement kit
without S4 ready sticker
(Spare part kit provided by
Barco with a set of 3 hard
disks configured to GEN1
storage controller).
On an ICMP with GEN1 storage
Controller:
RAID initialization does not need
to be performed.
Content can be ingested
immediately.
On an ICMP with GEN2 storage
Controller:
Only usable after RAID
initialization + restart.
Content can be ingested
immediately after restart.
RAID initialization needs to be
perform with Web Communicator.
immediately usable after RAID
initialization + restart (content
can be ingested).
Barco HDD replacement kit
with S4 ready sticker (New
Spare part kit provided by
Barco with a set of 3 hard
disks configured to GEN2
storage controller).
On an ICMP with GEN1 storage
Controller:
Only usable after RAID
initialization with Communicator +
restart (content can then be
ingested immediately).
On an ICMP with GEN2 storage
Controller:
RAID initialization does not need
to be performed.
Content can be ingested
immediately after restart.
RAID initialization does not need
to be performed.
Content can be ingested
immediately.
ICMP-X