EasyManuals Logo

Basler acA2040-55 User Manual

Basler acA2040-55
373 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #207 background imageLoading...
Page #207 background image
AW00123409000 Features
Basler ace USB 3.0 197
1. Set the Gain Selector to All.
2. Set the Gain parameter to your desired value.
You can set the Gain Selector parameter and the Gain parameter value from within your application
software by using the Basler pylon API. The following code snippet illustrates using the API to set
the selector and the parameter value:
camera.GainSelector.SetValue(GainSelector_All);
camera.Gain.SetValue(0.0359);
You can also use the Basler pylon Viewer application to easily set the parameters.For more
information about the pylon API and the pylon Viewer, see Section 3.1 on page 61.
To set the Gain parameter value using Basler pylon:
The minimum regular setting for the Gain parameter applies when the remove
parameter limits feature is not used.
The limits for the Gain parameter settings can be extended beyond the regular
lower and upper limits by using the remove parameter limits feature.
For more information about the remove parameter limits feature, see Section 7.4
on page 201.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Basler acA2040-55 and is the answer not in the manual?

Basler acA2040-55 Specifications

General IconGeneral
BrandBasler
ModelacA2040-55
CategoryDigital Camera
LanguageEnglish

Related product manuals