Features AW00123409000
234 Basler ace USB 3.0
set, that is sequencer set 2, into the active set. The parameter values for sequencer set 2
overwrite the parameter values for sequencer set 1 in the active set.
A frame acquisition is carried out using the parameter values of sequencer set 2. The image
data are processed and transmitted out of the camera.
The trigger signal assigned to path 1 stays high.
When the next frame start trigger signal was received the trigger signal assigned to path 1 is
found to be high. As a result, the frame start trigger triggers the loading of the next sequencer
set, that is sequencer set 3, into the active set. The parameter values for sequencer set 3
overwrite the parameter values for sequencer set 2 in the active set.
Note by comparison with previous frame start triggers that signal levels of the sequencer set
trigger assigned to path 1 that occur occur between frame start triggers have no effect on se-
quencer set advance.
An image acquisition is carried out using the parameter values of sequencer set 3. The image
data are processed and transmitted out of the camera.
The trigger signal assigned to path 1 goes low.
The trigger signal assigned to path 1 goes high.
When the next frame start trigger signal was received the trigger signal assigned to path 1 is
found to be high. As a result, the frame start trigger triggers the loading of the next sequencer
set, that is sequencer set 0, into the active set. The parameter values for sequencer set 0
overwrite the parameter values for sequencer set 3 in the active set. A new cycle of sequencer
sets starts.
An frame acquisition is carried out using the parameter values of sequencer set 0. The image
data are processed and transmitted out of the camera.
The trigger signal assigned to path 1 goes low.
When the sequencer feature was disabled by setting the Sequencer Mode parameter value to
Off, frame exposure and sensor readout were already complete but image transmission out of
the camera was not. In this case, the complete frame will be transmitted even after the
sequencer feature was disabled.
The previous sequencer parameter values, occurring in the active set before the sequencer fea-
ture was enabled, are loaded into the active set again, overwriting the parameter values of se-
quencer set 0.