AW00123409000 Features
Basler ace USB 3.0 243
The first Software Signal 1 trigger is sent. It will, however, only later become effective.
When the next frame start trigger signal was received sequencer set 1 is present in the active
set and is used for the image acquisition. The image data are processed and transmitted out of
the camera.
The first Software Signal 1 trigger becomes effective after some delay, loading sequencer set 0
into the active set and thereby resetting the cycling through the sequencer sets.
When the next frame start trigger signal was received sequencer set 0 is present in the active
set and is used for the image acquisition. The image data are processed and transmitted out of
the camera.
When the next frame start trigger signal was received sequencer set 0 is present in the active
set and is used for the image acquisition. The image data are processed and transmitted out of
the camera.
When the Sequencer Mode parameter value is set to Off the sequencer feature becomes
disabled for the application of sequencer sets during image acquisitions. The sequencer
parameter values that were the current ones before the sequencer feature was enabled, are
loaded into the active set again. The sequencer set 0 parameter values in the active set are
overwritten.