Operation
Becker Avionics
104 BD406/PBD406 DV16401.03 Issue 04 May 2021
Row ID
Display
Description - Config Menu View
5
+ 02 : 00
UTC OFFSET
5/7
[ HH : MM
]
STO - CONFIRM
UTC offset setting:
Availability of the function depends on configuration.
HH: hours
MM: minutes
Range: -12:00 … +14:00 with 00:15 resolution.
Turn rotary knob to change value.
Push STO key to store.
Sign is shown only if value is modified but not stored in memory.
6
12
.
2 [
V]
POWER SUPP 6/7
Power supply indicator:
Shows power supply voltage with resolution of 0.1 [V].
7
75
BRIGHTNESS 7
/
7
Backlight brightness regulation:
Availability of the function depends on configuration.
Brightness range 0...100.
o Progress bar is not filled: brightness value 0.
o Progress bar is fully filled: brightness value 100.
Turn rotary knob to change value.
Table 11: Mission Mode - Description Config Menu View