Error ID
Display
Description/Action
9
ERR
-
09 01/
03
CONFIGURATION
SETTINGS ERROR
Long press STO
to load default
Integrity of configuration settings is compromised.
Data are lost.
Contact service.
10
ERR
-10 01/03
OPERATION LOG
DATA ERROR
Press STO
to confirm
Operation data integrity error.
Data are lost.
Contact service.
11
ERR
-11 01/03
NAVPOINTS DB
FAILED
Long press STO
to clear DB
NavPoint database integrity error.
Data are lost.
Contact service.
12
ERR-12 01/03
GPS COMM
ERROR
Press STO
to confirm
GPS communication is lost. Internal or external GPS
receiver does not supply valid transmission. Make sure that
correct source is selected in installation setup.
Contact service.
WARN-
01
WARN-01 01/03
NEW BEACON
OVERWRITES OLD
Press STO
to confirm
Warning is shown:
In installation setup at FULL DB CONF screen STORE
NEW BEACON is selected.
AND
Database is full.
AND
New message from unregistered in database beacon is
received by the device.
Push STO to confirm.
WARN-
02
WARN-02 01/03
NEW BEACON
IGNORED
Press STO
to confirm
Warning is shown:
If in installation setup at FULL DB CONF screen IGNORE
NEW BEACON is selected.
AND
Database is full.
AND
A new message from unregistered in database beacon is
received by the device.
Push STO to confirm.
-
WARNING 01/01
NEW BEACON
DETECTED
Press STO
to confirm
Warning is shown:
When a new message from not registered in database
beacon is received.
Push STO to confirm.
-
INVALID INSTALL
DATA
LONG STO – DEFAULT
WARNING
Shown only in installation setup when CH or CM installation
data are corrupted (CRC error occurs).
Contact service.

Table of Contents