: Invalid reference signal, AEC Reference block (object code '__') at [__,__].
Explanation
: AEC Reference blocks cannot connect to their own AEC Input blocks
since this would amount to a feedback.
Messages
: DSP tasks for fixed allocations in unit #__ cannot be scheduled.
DSP tasks for gang #__ cannot be scheduled.
Explanation
: Either fixing the allocations or ganging the DSP blocks dictates that the
DSP blocks be located in the same Audia unit. However, in this case
it is not possible to distribute the DSP blocks among the available
DSPs in that unit. See also 'Allocation of DSP blocks to DSPs' below.
Allocation of DSP blocks to Audia Devices
Message
: Too many combinations. Try to reduce the number of groups by
combining DSP blocks.
Explanation
: The possibilities are too numerous to determine a solution within
a reasonable period of time. Reduce the number of groups by
ganging components together or giving them fixed allocations.
Message
: Group #__ has too many connections to be placed into an Audia
unit.
Explanation
: The specified group requires so many links to other groups that it
would exceed the limitations of CobraNet. Normally, the
number of CobraNet connections could be reduced by combining
the specified group with some other group(s). However, in this case,
it would require more resources than available in a single Audia unit.
Attempt to produce more compact groups, with fewer connections,
using fixed allocations and/or ganging. This can also happen if
CobraNet I/O blocks have been placed into a non-CobraNet unit.