121
Command
SET – Tells Audia
®
that a DSP attribute is to be set to a specific value – may contain negative number
and/or decimal points
GET - Tells Audia that a DSP attribute is to be read - Response may contain a decimal point and/or a
negative number.
INC - Tells Audia that a DSP attribute is to be incremented by a specific amount
DEC- Tells Audia that a DSP attribute is to be decremented by a specific amount
RECALL – Tells Audia that a preset is to be recalled.
DIAL – Tells the Audia that a dial command is being sent
SETL and GETL can be used if negative numbers and/or decimals are not supported by a control system.
SETL – Tells Audia that a DSP attribute is to be set to a specific value, no decimal places or negative
numbers – To convert a dB number: add 100 to the desired level and then multiply by 10.
Example: To set a level to –60.5dB, add 100 (-60.5 +100 = 39.5). Then multiply by 10 (39.5 X 10 =
395). Instead of Value being –60.5, Value after this SETL command will equal 395.
GETL - Tells Audia that a DSP attribute is to be read without negative numbers or decimals. To convert
this number to dB: divide the number by 10, then subtract 100.
Example: With a returned GETL response of 405, divide by 10 (405 / 10 = 40.5), then subtract 100
(40.5 – 100 = -59.5dB)
For your reference, the SETL/GETL table shows .5dB increments converted into the SETL/GETL format.
Some Attribute do not support all commands. The Attribute section defines which commands support
SET/SETL, GET/GETL, INC, or DEC functions. RECALL is only used on preset commands.
*When GET or GETL is used, a Value will not need to be specified since GET/GETL is a request command.
A Value must be specified in order for strings with SET/SETL, INC, DEC, and RECALL to work.