Field Description
numbers.
DSCP/TOS Filter
(Layer 3)
Select the Type of Service (TOS).
Possible values:
# (default value): The type of service is ignored.
56 :( E1: Differentiated Services Code Point
according to RFC 3260 is used to signal the priority of IP
packets (indicated in binary format, 6 bit).
56 5%1 E1: Differentiated Services Code Point
according to RFC 3260 is used to signal the priority of IP
packets (indicated in decimal format).
56 ?>%1 E1: Differentiated Services Code
Point according to RFC 3260 is used to signal the priority of
IP packets (indicated in hexadecimal format).
*- :( E1: The TOS value is specified in binary
format, e.g. 00111111.
*- 5%1 E1: The TOS value is specified in decimal
format, e.g. 63.
*- ?>%1 E1: The TOS value is specified in
hexadecimal format, e.g. 3F.
COS Filter
(802.1p/Layer 2)
Enter the service class of the IP packets (Class of Service,
CoS).
Possible values are whole numbers between and ,.
The default value is #.
12.5.2 Rule Chains
Rules for IP filters are configured in the Rule Chains menu. These can be created separ-
ately or incorporated in rule chains.
In the Networking->Access Rules->Rule Chains menu, all created filter rules are listed.
12 Networking bintec elmeg GmbH
252 bintec RS Series

Table of Contents

Related product manuals