The encoder signal assignment to the inputs is based on clock‐
wise rotation (front view toward motor shaft).
Track A (A+, A-) advances track B (B+, B-) 90° electrically.
The actual position value increases (prerequisite: negation
of the encoder signals was not parameterized).
If available, the reference track R (R+, R-) provides the refer‐
ence mark pulse at positive signals of track A and track B (in
the so-called "0-th" quadrant).
Standard setting: See Functional Description of firmware.
DOK-INDRV*-CXX02******-PR03-EN-P Bosch Rexroth AG 99/143