4-34 100-214-276 Rev. 3
Chapter 4: Installation and Setup
Assemble the Acoustic Stack
4.8.1 For a 15 kHz System
4.8.2 For a 20kHz System
Step Action
1
Clean the mating surfaces of the converter, booster, and horn. Remove any
foreign material from the threaded holes.
2
Install the threaded stud into the top of the booster. Torque to 450 in-lbs,
50.84Nm. If the stud is dry, apply 1 or 2 drops of a light lubricating oil before
installing.
3
Install the threaded stud into the top of the horn. Torque to 450 in-lbs, 50.84Nm.
If the stud is dry, apply 1 or 2 drops of a light lubricating oil before installing.
4
Install a single Mylar washer (matching the size of the washer to the stud) to
each interface.
5 Assemble the converter to the booster and the booster to the horn.
6 Torque to 250 in-lbs, 28.25 Nm.
Step Action
1
Clean the mating surfaces of the converter, booster, and horn. Remove any
foreign material from the threaded holes.
2
Install the threaded stud into the top of the booster. Torque to 450 in-lbs, 50.84
Nm. If the stud is dry, apply 1 or 2 drops of a light lubricating oil before installing.
3
Install the threaded stud into the top of the horn.Torque to 450 in-lbs, 50.84 Nm.
If the stud is dry, apply 1 or 2 drops of a light lubricating oil before installing.
4
Install a single Mylar washer (matching the size of the washer to the stud) to
each interface.
5 Assemble the converter to the booster and the booster to the horn.
6
Torque to 220 in-lbs, 24.85 Nm. (Torque 20kHz Solid Mount Converter to 250 in-
lbs, 28.25Nm.)
DOC EXPIRES 12PM 7/24/2012. Article or Material must comply with the requirements
stipulated by RoHS in its current version

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Branson 2000X Series and is the answer not in the manual?

Branson 2000X Series Specifications

General IconGeneral
Frequency20 kHz
Overload ProtectionYes
Frequency Range19.5 kHz to 20.5 kHz
Voltage50/60 Hz
Operating Temperature0 - 40° C