3 USING THE OPERATION PANEL AND SWITCHES
BM-2000
9
3.2.1 Parameter list
Some of the parameters are set once for each program (and are common to all steps in that program), and other parameters are set
individually for each step.
[Program parameters]
Parameter
Setting range
Unit
Initial value
Glue thickness
(Thickness of the glue)
50 - 200 [um]
10 [um]
80 [um]
Nozzle space
(Clearance between the
nozzle and the roller under
nozzle)
0.10 - 2.50 [mm]
0.05 [mm]
0.50 [mm]
Comment
(Comment string for program
which is displayed on the
screen)
Up to 24 alphanumeric
characters
--
Not input
[Step parameters]
Parameter
Setting range
Unit
Initial value
Upper roller feed speed
0.50 - 5.00 [m/min]
0.01 [m/min]
1.00 [m/min]
Lower roller feed speed
0.50 - 5.00 [m/min]
0.01 [m/min]
1.00 [m/min]
Upper cloth glue-free width
-50 - +50
1
0
Lower cloth glue-free width
-50 - +50
1
0
Anti stop mark
1 - 10
1
1