3 USING THE OPERATION PANEL AND SWITCHES
BM-2000
24
3.5.4 List of memory switch settings (for operators)
No.
Name
Setting
Setting range
Unit
Initial
value
208
Pump speed during test
mode
Pump speed during test mode
5 - 50 [rpm]
5
40
211
Automatic discharge time in
test mode (F1)
Glue discharge time when F1 is
pressed during test mode
10 1800 [s]
5
30
212
Automatic discharge time in
test mode (F2)
Glue discharge time when F2 is
pressed during test mode
10 1800 [s]
5
80
213
Automatic discharge time in
test mode (F3)
Glue discharge time when F3 is
pressed during test mode
10 1800 [s]
5
600
214
Automatic discharge time in
test mode (F4)
Glue discharge time when F4 is
pressed during test mode
10 1800 [s]
5
180
215
Automatic discharge time in
test mode (F5)
Glue discharge time when F5 is
pressed during test mode
10 1800 [s]
5
180
221
Assignment No. for F1 key
Program number selected when F1 is
pressed at the home screen
OFF,
1 - 30
1
OFF
222
Assignment No. for F2 key
Program number selected when F2 is
pressed at the home screen
OFF,
1 - 30
1
OFF
223
Assignment No. for F3 key
Program number selected when F3 is
pressed at the home screen
OFF,
1 - 30
1
OFF
224
Assignment No. for F4 key
Program number selected when F4 is
pressed at the home screen
OFF,
1 - 30
1
OFF
225
Assignment No. for F5 key
Program number selected when F5 is
pressed at the home screen
OFF,
1 - 30
1
OFF
226
Assignment No. for F6 key
Program number selected when F6 is
pressed at the home screen
OFF,
1 - 30
1
OFF
231
Program/Step changing
method
1: Change step with knee switch
2: Change step with knee switch and
change program with Op hand
switch
3: Change program with knee switch
1 - 3
1
1
255
Feed speed decrease rate
Upper roller speed deceleration rate
when feed speed adjustment switch is
moved down
-10.0 - 0.0[%]
0.1
0.0
256
Feed speed increase rate
Upper roller speed acceleration rate
when feed speed adjustment switch is
moved up
0.0 - 10.0[%]
0.1
0.0
301
Auto sleep mode
Automatic sleep mode
OFF, ON
-
ON
302
Elapsed time before entering
auto sleep mode
Standby time until automatic sleep
mode is entered
15 - 60 [min]
15
30
400
Speed of edge control roller
Edge control roller rotation speed
10 - 300 [rpm]
10
50
401
Upper edge controller
Upper edge controller
OFF: Disabled ON: Enabled
OFF, ON
-
ON
402
Lower edge controller
Lower edge controller
OFF: Disabled ON: Enabled
OFF, ON
-
ON
411
Nozzle lever - Glue position
adjustment
Adjustment value for glue position
-120 - 120
4
0
413
Nozzle lever
Nozzle lever motor speed
60 - 300 [rpm]
10
300
421
X-over bonding
X-over detection function
ON: Enabled, OFF: Disabled
OFF, ON
-
OFF
422
Sensitivity of the X-over
bonding detection sensor
X-over detection sensor sensitivity
0.5 - 2.0
0.1
1.0
424
X-over bonding - Cloth plate
lowering amount
Distance that cloth plate is lowered
when an X-over seam is detected
(AUTO: Lowering amount = clearance
setting value)
AUTO,
0.1 - 2.00 [mm]
0.02
AUTO
426
X-over detection - cloth plate
lowering position correction
Correction distance for cloth plate
lowering position when an X-over
seam is detected
-11.0 - 20.0 [mm]
0.1
0.0

Table of Contents