3 USING THE OPERATION PANEL AND SWITCHES
BM-2000
26
No.
Name
Setting
Setting range
Unit
Initial
value
573
Minimum upper roller
pressure
Upper roller pressure lower limit
1 - 60[N]
1
3
574
Maximum upper roller
pressure
Upper roller pressure upper limit
1 - 60[N]
1
20
575
Minimum pump pressure
Pump pressure lower limit
0.00 - 0.10
[MPa]
0.01
0.00
576
Maximum pump pressure
Pump pressure upper limit
1.003.00
[MPa]
0.10
2.50
596
Nozzle position confirmation
Glue discharge when the nozzle is
raised when gluing starts. ON: Not
discharged, OFF: Discharged
OFF, ON
-
ON
650
Time duration until the
buzzer stops
OFF: Buzzer does not stop
OFF
5 - 15[s]
5
OFF
652
Maximum duration of
continuous bonding
OFF: Disabled
1 - 30: If bonding time exceeds the
maximum value, it will be
paused and error occurs.
OFF,
1 - 30[min]
1
3
759
Time duration until closing
cartridge valve
Time until the cartridge valve is closed
0.1 - 10.0[s]
0.1
5.0
850
Language
Language setting
0: English 1: Japanese 2: Chinses
0 - 3
1
-
865
Upper roller lift up during
reverse mode
Lift up the upper roller during reverse
mode.
OFF, ON
-
ON