9-11
Error Code
(Hex)
Symptom Probable Cause Solution
Document front sensor 2
defective
Replace the document
front sensor 2.
BF Duplex scanning cannot be
implemented due to too long
document
Main PCB defective Replace the main PCB.
C1-CF Not used.
D0-DF Modem error
Main PCB defective Replace the main PCB.
E0-E5 Not used.
E6 Write error in EEPROM
Main PCB defective Replace the main PCB.
E7 Not used.
CCD unit defective Replace the CCD unit.
E8 Data scanning error during
transmission.
Main PCB defective Replace the main PCB.
E9 Not used.
Document front sensor
actuator does not move
smoothly.
Set the document front
sensor actuator into place.
ADF relay PCB defective Replace the ADF relay
PCB.
Document front sensor
defective
Replace the document
front sensor.
EA Document removed at phase
B.
Main PCB defective Replace the main PCB.
EB-FF Not used.