App. 4-39 Confidential
WSW35
(Function setting 13)
Selector
No.
Function Setting and Specifications
1
|
4
Max. detection period of dial
tone/busy tone during recording of
ICM (Not used.)
No. 1 2 3 4
0 0 0 0 : No detection
0 0 0 1 : 1 sec.
0 0 1 0 : 2 sec.
0 1 0 0 : 4 sec.
| |
1 1 1 1 : 15 sec.
5
|
8
Not used.
NOTE: Selectors 1 through 4 are applicable to models equipped with internal TADs.
- Selectors 1 through 4: Max. detection period of dial tone/busy tone during recording of ICM
(Not used.)
If the machine (called station) detects dial tone or busy tone exceeding the detection level specified
by selectors 1 through 3 on WSW30 for the period specified by these selectors, then it disconnects
the line.