3-33
Confidential
■ Error code B1
Dark level offset data level error for scanning
* This error is indicated on the LCD in the maintenance mode.
Error code B2
Gain control data level error for scanning
* This error is indicated on the LCD in the maintenance mode.
Error code B7
A/D converter standard voltage failure; at High side
* This error is indicated on the LCD in the maintenance mode.
Error code B8
A/D converter standard voltage failure; at Low side
* This error is indicated on the LCD in the maintenance mode.
Scanner Error
Scanner Error
Scanner Error
Scanner Error
Step Cause Remedy
1
CCD unit failure Replace the CCD module. (CCD model)
Replace the document scanner unit.
(CIS model)
2 Main PCB failure Replace the main PCB ASSY.