App. 1-18
Confidential
<WSW12> (Signal detection condition setting)
* 1000 ms in Chinese models.
Selectors 1 through 4:Min. detection period required for interpreting incoming
calling signal (CI) as OFF
Max. detection period for incoming calling signal (CI) being
OFF
If the machine detects the OFF state of a CI signal for the period greater than the value set
by selectors 1 and 2 and less than the value set by selectors 3 and 4, it interprets the CI
signal as OFF.
Selectors 5 and 6: Min. detection period required for acknowledging incoming
calling signal (CI) as ON
These selectors set the period required to make the machine acknowledge itself to be
called. That is, if the machine continuously detects a CI signal with the frequency set by
selectors 1 through 4 on WSW14 during the period set by these selectors 5 and 6, then it
acknowledges the call.
Selector 7: Line connection timing
If a line is connected in a ringer-ON period, FAX models equipped with SDAA circuits may
malfunction due to the ringer voltage. To make the line connection stable, this selector
should be set to "0" so that a line is connected in a ringer-OFF period.
Selector No. Function Setting and Specifications
1
2
Min. detection period required
for interpreting incoming calling
signal (CI) as OFF
No. 1 2
0 0: 1500 ms
0 1: 500 ms
1 0: 700 ms
1 1: 900 ms
3
4
Max. detection period for
incoming calling signal (CI)
being OFF
No. 3 4
00: 6 sec.
01: 7 sec.
10: 9 sec.
1 1: 11 sec.
5
6
Min. detection period required
for acknowledging incoming
calling signal (CI) as ON
No. 5 6
0 0: 800 ms (1000 ms*)
0 1: 200 ms
1 0: 250 ms
1 1: 150 ms
7 Line connection timing
0: Ringer-OFF 1: Ringer-ON
period period
8 Not used.

Table of Contents

Other manuals for Brother MFC-8480DN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brother MFC-8480DN and is the answer not in the manual?

Brother MFC-8480DN Specifications

General IconGeneral
Print technologyLaser
Maximum resolution1200 x 1200 DPI
Economical printingYes
Print speed (black, normal quality, A4/US Letter)32 ppm
Grayscale levels256
Input color depth48 bit
Image formats supportedBMP, JPG, TIF
Maximum scan resolution19200 x 19200 DPI
Optical scanning resolution600 x 2400 DPI
Copier resize25 - 400 %
Maximum number of copies99 copies
Copy speed (black, normal quality, A4)32 cpm
FaxingMono faxing
Fax memory600 pages
Modem speed33.6 Kbit/s
Power supply typeAC
Weight (imperial)40.3 lbs
Dimensions (WxDxH)530.8 x 449.5 x 474.9 mm
Power requirements110 - 240V, 50/60 Hz
All-in-one functionsCopy, Fax, Scan
Standard media sizes2.75'' - 8.5\
Maximum internal memory0.576 GB
Color all-in-one functionsscan, n
Compatible operating systemsWindows OS Mac OS
Package dimensions (W x D x H)24.7 x 22.3 x 22.6 \
Total input capacity250 sheets
Total output capacity150 sheets
Auto document feeder (ADF) input capacity50 sheets
DisplayLCD
Market positioningBusiness
Internal memory64 MB
Sound pressure level (copying)56 dB
Sound pressure level (printing)30 dB
Maximum print size216 x 356 mm
Paper tray media typesBond paper, Envelopes, Plain paper, Recycled paper, Transparencies
Non-ISO print media sizesExecutive
ISO A-series sizes (A0...A9)A4, A5, A6
ISO B-series sizes (B0...B9)B5, B6
Maximum ISO A-series paper sizeA4
Supported network protocols (IPv4)ARP, RARP, BOOTP, DHCP, APIPA, LLMNR, LPR/LPD, IPP/IPPS, FTP, HTTP/HTTPS, SSL/TLS, TFTP, SMTP, APOP, POP, SMTP, SMTP-AUTH, SNMPv1/v2c/v3, ICMP, LLTD, CIFS, SNTP, NDP, RA, DNS, mDNS, ICMPv6
Standard interfacesUSB 2.0
USB 2.0 ports quantity1
Power consumption (standby)18 W
Power consumption (average operating)680 W
Package weight21645 g
Sustainability certificatesENERGY STAR
Maximum duty cycle30000 pages per month
Recommended duty cycle3500 pages per month
Operating temperature (T-T)10 - 32.2 °C
Operating relative humidity (H-H)20 - 80 %