SMART KTF 2000 – KTF/RW Operation
3B-24 - SMART KTF 2000
1.2) ERR TENSION = P1.2
Press
to enable the parameter programming.
VV.V = Value of ERROR TENSION parameter to be associated to the article
setup. It indicates the Tolerance Range of Tension beyond which the
machine will be stopped. The error signalling as well as the machine stop
occur only if the tolerance is exceeded for the period of time indicated by
the next parameter 1.3) TIME ALARM.
Choose the desired value using
, ,
[allowed values 0.1 (value of MAIN TENSION parameter)].
Press
to move to the next parameter.
1.3) TIME ALARM = P1.3
Press
to enable the parameter programming
VV.V = Value of P1.3 TIME ALARM parameter to be associated to the article
setup. It indicates the maximum time (in seconds) during which the
tension value may exit from the tolerance range set by the 1.2) ERR
TENSION parameter. You can disable (OFF) or re-enable this feature by
pressing
.
Choose the desired value using
, ,
[allowed values: 0.1 to 10 sec.].
Press
to move to the next parameter.
1.4) TENS INC-DEC = P1.4
Press
to enable the parameter programming
VV.V = Value of parameter P1.4 INC-DEC TENSION parameter to be
associated to the article setup. It indicates the increment/decrement
resolution of the Tension graduated by the external INC/DEC command
pulses..
Choose the desired value using , ,
[allowed values: 0.1 to 10 grams].
Press
to move to the next parameter.