User Manual – Rev AJ California Instruments
END DELAY This is the time delay the voltage level will stay at the END
level before it proceeds with the next transient event or
completes the transient.
FUNCTION [3Pi controller only] This field can be used to select the wave
shape to be used during this step of the transient sequence.
ape from the available
each step and remains in effect for the duration of the step. The
ine wave).
transient event
e transient edit screen. All data
to
tion of an EVENT later if needed. (For example,
VOLT
Each step can use a different wave sh
library of 50 user-defined waveforms or the three standard
waveforms. The output wave shape changes upon entry into
default wave shape is always the SINE (s
REPEAT This is the number of times the SURGE/SAG
will repeat before it will proceed to the next event or exit the
transient program. Note that the number of times the transient
event is generated is equal to the REPEAT + 1. Leave this
value at zero if only one execution of this event in the list is
required.
EVENT # This must be the last item in th
fields must be entered before inserting the EVENT #. The
EVENT # takes a value from 1 to 99. The EVENT # defines the
order of execution of the transient events in a multiple event
transient. It is a good practice to enter spaced EVENT #’s
allow inser
space them by 5.) Entry of a sequence EVENT # number will
cause the display to return to the TRANSIENT screen.