System Specifications
Vibrex 2000 and Vibrex 2000 Plus User Guide 13
2.3.2 Vibrex 2000 Plus Specifications
The table, starting below, lists complete technical specifications for the
Vibrex 2000 Plus system.
Environmental Conditions
Temperature 0°C to 50°C
Electromagnetic
interference (EMI)
susceptibility and
radiated emissions
standards
Industrial Electronic Control Equipment
Class certified to
• Class Standard EN50081-2
• Standard EN50082-2
Characteristic Specifications
Basic Specifications
Data storage capacity 1 Mb
Built-in test (BIT)
coverage
Memory check and calibration on power
up; user-initiated tests (with
STATUS
key)
check battery and sensor power
NOTE: Errors are logged to a
printable fault log.
Date and time stamping Yes
Log (data) files -
contents and formats
Balance jobs, log book, balance, spectrum,
fault log, all in ASCII format
Compatible software
(ground based)
Chadwick-Helmuth V2K Download and
V2K Plot programs
Basic Performance
Frequency range 0 to 10,000 Hz
Characteristic Specifications (Continued)