Propeller Balancing
Vibrex 2000 and Vibrex 2000 Plus User Guide 81
5.4.3 Obtaining Balance Solutions
After the balance reading displays and the user presses the START key,
the Vibrex unit presents its recommended weight change solution (in
grams) at a specific clock angle.
The illustration below shows an example of a typical Vibrex unit’s
Solution screen.
5.4.3.1 Application Guidelines
In applying balance solutions, use the following guidelines:
• There may be some cases where the user cannot physically place the
weight at a specified location, or the user must add balance weights
different from those specified. To account for these variations, the
user must input the weight and clock angle of the actual adjustment
into the Vibrex unit.
• If the specified weight differs from that added to the propeller or the
angle placement is different than that specified in the solution, the
user must change the values. Just enter the actual applied weight and/
or angle.
CAUTION: Failure to enter the actual values used degrades the
next solution and may not improve the propeller’s balance.
next run, push START
AT [ 1:29 ] (split)
FOLLOW INSTRUCTIONS
RUN 1 ADJUSTMENT
ADD [ 5.2 ] GMS
VIEW PROP MEASURMENT
SELECT TO VIEW
MEASUREMENTS
AGAIN
SELECT TO
ENTER ACTUAL
WEIGHT ADDED
(IN GRAMS)
SELECT TO
ENTER ACTUAL
ANGLE USED
SELECT FOR PROPELLER
PROTRACTOR
INSTRUCTIONS