32 Chadwick-Helmuth Company, Inc.
Chapter 3 - Getting Started
Printing Spectrum Measurements -
The user has the following
choices under the
PRINT SPECTRUM
soft key:
<CURRENT LIST>
Prints the latest measurement stored to
memory.
<ALL LISTS>
Prints all spectrum lists stored to memory.
<PEAK LIST>
Prints the 10 highest peaks for a spectrum with
the information block for the acquisition.
<ORDER LIST>
Prints the order list of half through 12
th
orders
in half increments, if an azimuth signal was
present with the information block for the
acquisition.
<RAW FFT>
Prints the vibration energy in each of the
400 bins of the FFT with the information block
for the acquisition.
NOTE: It is not advisable to print the
RAW FFT
data, using a
thermal printer. Use this feature primarily for PCs with their own
software programs that generate graphic spectra.
Printing Status Information and Fault Log -
The user may print
Vibrex unit status information, as follows:
1. From the Main Menu screen, press
STATUS
. Allow the Vibrex unit to
complete its battery voltage and sensor power tests.
The Vibrex 2000 gives the user its test results by showing the battery
voltage and an OK or the FAIL message for sensor power.
2. Make sure to set up the printer then press
PRINT.
The resulting printout shows the status of the Vibrex 2000 or
Vibrex 2000 Plus and includes a fault log. If the unit cannot operate or if
there is an error in operation, the Vibrex unit makes an appropriate entry
in the fault log. For help in interpreting the fault log, contact Chadwick-
Helmuth Customer Support.