EasyManuals Logo

Chroma 63600-2 User Manual

Default Icon
258 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #198 background imageLoading...
Page #198 background image
Programmable DC Electronic Load 63600 Series Operation & Programming Manual
5-66
LOAD:PROTection:CLEar
Type: Channel-Specific
Description: This command resets the status of electronic load.
Setting Syntax: LOAD:PROTection:CLEar
Setting Parameters:None
Setting Example: LOAD:PROT:CLE
Query Syntax: None
LOAD:SHORt[:STATe]
Type: Channel-Specific
Description: Activate or inactivate short-circuited simulation.
Setting Syntax: LOAD:SHORt[:STATe]<space><NRf>
Setting Parameters:<NRf>, OFF(0), ON(1)
Setting Example: LOAD:SHOR ON Activate short-circuited simulation.
LOAD:SHOR OFF Inactivates short-circuited simulation.
Query Syntax: LOAD:SHORt[:STATe]?
Return Parameters:<CRD>, OFF, ON
Query Example: LOAD:SHOR?
LOAD:SHORt:KEY
Type: Channel-Specific
Description: Set the mode of short key in the electronic load.
Setting Syntax: LOAD:SHORt:KEY<space><NRf>
Setting Parameters:<NRf>, HOLD(0), TOGGLE(1)
Setting Example: LOAD:SHOR:KEY TOGGLE Set the short key mode to Toggle.
LOAD:SHOR:KEY HOLD Set the short key mode to Hold.
Query Syntax: LOAD:SHORt:KEY?
Return Parameters:<CRD>, HOLD, TOGGLE
Query Example: LOAD:SHOR:KEY?

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chroma 63600-2 and is the answer not in the manual?

Chroma 63600-2 Specifications

General IconGeneral
BrandChroma
Model63600-2
CategoryPower Supply
LanguageEnglish

Related product manuals