Programmable DC Electronic Load 63600 Series Operation & Programming Manual
LOAD:PROTection:CLEar
Type: Channel-Specific
Description: This command resets the status of electronic load.
Setting Syntax: LOAD:PROTection:CLEar
Setting Parameters:None
Setting Example: LOAD:PROT:CLE
Query Syntax: None
LOAD:SHORt[:STATe]
Type: Channel-Specific
Description: Activate or inactivate short-circuited simulation.
Setting Syntax: LOAD:SHORt[:STATe]<space><NRf>
Setting Parameters:<NRf>, OFF(0), ON(1)
Setting Example: LOAD:SHOR ON Activate short-circuited simulation.
LOAD:SHOR OFF Inactivates short-circuited simulation.
Query Syntax: LOAD:SHORt[:STATe]?
Return Parameters:<CRD>, OFF, ON
Query Example: LOAD:SHOR?
LOAD:SHORt:KEY
Type: Channel-Specific
Description: Set the mode of short key in the electronic load.
Setting Syntax: LOAD:SHORt:KEY<space><NRf>
Setting Parameters:<NRf>, HOLD(0), TOGGLE(1)
Setting Example: LOAD:SHOR:KEY TOGGLE Set the short key mode to Toggle.
LOAD:SHOR:KEY HOLD Set the short key mode to Hold.
Query Syntax: LOAD:SHORt:KEY?
Return Parameters:<CRD>, HOLD, TOGGLE
Query Example: LOAD:SHOR:KEY?