Remote Operation
5-65
5.3.2.9 LOAD Subsystem
:LOAD
:SHORt
:STATe
SP
?
<CRD>
<NR1>
<CRD>
SP
?
OFF / 0
ON / 1
:STATe
:PROTection
:CLEar
OFF / 0
ON / 1
?
:KEY
SP
?
<CRD>
HOLD / 0
TOGGLE / 1
LOAD[:STATe]
Type: Channel-Specific
Description: The LOAD command makes the electronic load active/on or
inactive/off.
Setting Syntax: LOAD[:STATe]<space><NRf>
Setting Parameters:<NRf>, OFF(0), ON(1)
Setting Example: LOAD ON Activate the electronic load.
LOAD 0 Inactivate the electronic load.
Query Syntax: LOAD[:STATe]?
Return Parameters:<CRD>, OFF, ON
Query Example: LOAD?
LOAD:PROTection?
Type: Channel-Specific
Description: This command returns the status of electronic load.
Setting Syntax: None
Setting Parameters:None
Setting Example: None
Query Syntax: LOAD:PROTection?
Return Parameters:<NR1>
Bit Position
15~9
8
7
6
5
4
3
2
1
0
Condition
REMOTE INHIBIT
FAN
MAX LIM
SYNC
REV
OPP
OCP
OVP
OTP
Bit Weight
256
128
64
32
16
8
4
2
1
Query Example: LOAD:PROT?