EasyManua.ls Logo

Chroma 63600-2 - IMPEDANCE Subsystem

Default Icon
258 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Operation
5-63
FETCh:ALLVoltage:MAX?
Type: Channel-Independent
Description: Returns the maximum voltage measured at the input of all load
modules. The return value is 0 when the channel does not exist.
Query Syntax: FETCh:ALLVoltage:MAX?
Return Parameters:<aard>, [Unit = Voltage]
Query Example: FETC:ALLV:MAX?
Return Example: 0, 0, 0, 0, 0, 0, 5.12, 0, 12, 0
FETCh:ALLVoltage:MIN?
Type: Channel-Independent
Description: Returns the minimum voltage measured at the input of all load
modules. The return value is 0 when the channel does not exist.
Query Syntax: FETCh:ALLVoltage:MIN?
Return Parameters:<aard>, [Unit = Voltage]
Query Example: FETC:ALLV:MIN?
Return Example: 0, 0, 0, 0, 0, 0, 5.12, 0, 12,0
5.3.2.8 IMPEDANCE Subsystem
:
STATic
:RL
:RS
:LS
SP
<NRf+>
?
SP
MAX
MIN
SP
<NRf
+>
?
SP
MAX
MIN
<NR2>
Suffix
<NR2
>
<NR2>
<NR2>
<NR2>
<NR2>
:
IMPedance
:CL
Suffix
SP
<
NRf+>
?
SP
MAX
MIN
<NR
2>
Suffix
<
NR2>
<NR2>
SP
<NRf+>
?
SP
MAX
MIN
<NR
2>
<NR2>
<NR2>
Suffix
IMPedance:STATic:CL
Type: Channel-Specific
Description: Set the equivalent parallel load capacitance for constant impedance
mode.
Setting Syntax: IMPedance:STATic:CL<space><NRf+>[suffix]
Setting Parameters:<NRf+>, 30μF ~ 50,000μF, Resolution = 1uF, Unit = Farad
Setting Example: IMP:STAT:CL 0.02 Set capacitance = 20mF.
IMP:STAT:CL 100μF Set capacitance = 100μF.

Table of Contents