EasyManuals Logo

Chroma 63600-2 User Manual

Default Icon
258 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #213 background imageLoading...
Page #213 background image
Remote Operation
5-81
5.3.2.17 SYNCHRONOUS Subsystem
:SYNChronous
:CHANnel
SP
<NRF+>
:RUN
:TYPE
SP
OFF / 0
ON / 1
NONE / 0
MASTER / 1
SLAVE / 2
SP
SYNChronous:CHANnel
Type: All Channels
Description: Set the specified channel to T1 & T2 in sync dynamic mode for
parallel loading.
Setting Syntax: SYNChronous:CHANnel<space><NRf+>
Setting Parameters:<NRf+>, 1 ~ 10
Setting Example: SYNC:CHAN 1 Set the specified channel to "1".
SYNC:CHAN MAX Set the specified channel to "10".
SYNC:CHAN MIN Set the specified channel to "1".
SYNChronous:RUN
Type: All Channels
Description: Set all electronic loads to “ON” in sync. parallel run.
Setting Syntax: SYNChronous:RUN<space><NRf>
Setting Parameters:<NRf>, OFF(0), ON(1)
Setting Example: SYNC: RUN ON Set the load to “ON” on sync. parallel.
SYNC: RUN OFF Set the load to “OFF” on sync. parallel.
SYNChronous:TYPE
Type: All Channels
Description: Set the specified mainframe to master or slave for sync. in parallel
run.
Setting Syntax: SYNChronous:TYPE<space><NRf>
Setting Parameters:<NRf>, NONE(0), MASTER(1), SLAVE(2)
Setting Example: SYNC:TYPE MASTER Set the mainframe to master for sync.
in parallel run.
SYNC:TYPE SLAVE Set the mainframe to slave for sync. in
parallel run.
SYNC:TYPE NONE Disables the mainframe to sync.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chroma 63600-2 and is the answer not in the manual?

Chroma 63600-2 Specifications

General IconGeneral
BrandChroma
Model63600-2
CategoryPower Supply
LanguageEnglish

Related product manuals