5.3.2.11 MODE Subsystem
:MODE
SP
CCM CCH
CRL
?
<CRD
>
CRM
CRH
CVL
CVM CVH
CPL
CPM
CPH
CZL
CZM CZH
CCDL
CCDM CCDH
CCFSL
CCFSM CCFSH
TIML TIMM
TIMH
SWDL
SWDM SWDH
OCPL OCPM OCPH
PROG
CCL
MPPTL MPPTM MPPTH
UDWL UDWM UDWH
MODE
Type: Channel-Specific
Description: This command sets the operational mode for the electronic load.
Setting Syntax: MODE<space><NRf>
Setting Parameters:<CRD>, CCL, CCM, CCH, CRL, CRM, CRH, CVL, CVM, CVH, CPL,
CPM, CPH, CZL, CZM, CZH, CCDL, CCDM, CCDH, CCFSL,
CCFSM, CCFSH, TIML, TIMM, TIMH, SWDL, SWDM, SWDH,
OCPL, OCPM, OCPH, PROG, MPPTL, MPPTM, MPPTH, UDWL,
UDWM, UDWH
Example: MODE CCL Set CC mode of low range.
MODE CCH Set CC mode of high range.
MODE CCDL Set CC dynamic mode of low range.
MODE CCDH Set CC dynamic mode of high range.
MODE CRL Set CR mode of low range.
MODE CRH Set CR mode of high range.
Query Syntax: MODE?
Return Parameters:<CRD>, CCL, CCM, CCH, CRL, CRM, CRH, CVL, CVM, CVH, CPL,
CPM, CPH, CZL, CZM, CZH, CCDL, CCDM, CCDH, CCFSL,
CCFSM, CCFSH, TIML, TIMM, TIMH, SWDL, SWDM, SWDH,
OCPL, OCPM, OCPH, PROG, MPPTL, MPPTM, MPPTH, UDWL,
UDWM, UDWH
Query Example: MODE?

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chroma 63600-2 and is the answer not in the manual?

Chroma 63600-2 Specifications

General IconGeneral
BrandChroma
Model63600-2
CategoryPower Supply
LanguageEnglish

Related product manuals